Three synthesis (temperature / humidity / vibration compound test machine)

Three synthesis (temperature / humidity / vibration compound test machine)

share

Three synthesis (temperature / humidity / vibration compound test machine)

  • Specifications
  • Parameters



Features:this device complies with mil STD, GB, JIS, JEDEC, such as IEC testspecification; the introduction of foreign technology, key components andmaterials imported (air spring, epoxy resin, stainless steel plate, rubbershock absorber, etc.), products exported to Europe, America and other overseascountries. Built-in support for air spring bearing and bearing capacity; earshaft of the air spring vibration isolation, linear guide bearing; made by useof finite element analysis without moving coil framework and more effectiveimprove dynamic resonance frequency and reduce the mass of moving parts.Platform equipped with emergency stop switch and air spring pressure adjustingvalve, pressure gauge, convenient user trials; platform using automotive painttechnology (metallic paint), paint, with long term Anti grinding rust role.


Specifications:Temperaturerange: -70℃~150

Temperature control stability: ±0.5

Temperature deviation: ±2

Heating temperature range: -40℃→125 about 33minutes, the temperature range can be linear heating up speed is 1℃~3 (with 42Kgor 300W active load), the maximum heating rate is 5/min (Full average)

Cooling temperature range: 125℃→ -40 about 33minutes, the temperature range can be linear heating up speed is 1℃~3 (with 42Kgor 300W active load) and maximum cooling rate is 5/min (Full average)

Humidity range: 20% ~ 98%RH

Humidity control stability: ±2%RH

Humidity distribution uniformity: ±3%RH(no-load) ±5%RH(no load)